Insertion models are a very good choice for large pipe sizes if used as insertion meters. They include a 3/16" drill bit, a 5/16" hex wrench, and a half-ring of the appropriate size to match your meter. Thermal flowmeters are most commonly applied to measure pure gases, such as would be used for laboratory experiments, and in semi-conductor production. Ultrasonic Insertion Flow Meter, Product In-Stock: Monterey, CA 93940, Toll-Free USA: 1-800-866-0200

We make this monitoring cost-effective and easy to implement by providing flowmeters that install in minutes, a wireless networking system, free monitoring software and hot tap meters for systems that cannot be shut down. Learn about Thermal Flowmeters for Compressed Air. The QuadraTherm® 640i is the most accurate insertion-probe thermal mass flow meter for air / gas mass flow rate measurement on the market today, achieving gas mass flow rate accuracy never before possible, +/- 0.75% of reading above 50% of full scale. There are no videos to display at this time. CDI 6400 flowmeters make localized metering of air usage a practical way to manage a compressed-air system. It includes a 3/16" drill bit, 3/16" and 1/4" hex wrenches, and an aluminum drill guide. Integral Mechanism Allows for Precise Paddle Insertion into the Pipe, Suitable for Installation into 1½...100 Inch Pipes, Copyright © 2020 KOBOLD Instruments, Inc. All Rights Reserved, ADI-1 - Universal Input LED Display Controller, ZOK - Totalizer Batcher and Monitor Electronics, Flowmeters, flow switches and flow transmitters, Pressure gauges, pressure transmitters and pressure switches, Level switches, float switches, level gauges, level transducers, level indicators and level transmitters, Temperature switches, temperature gauges and temperature transmitters, Accessories, including magnetic filters, needle valves, regulating valves, control devices and relays. 1-inch (25.4 mm) diameter protective sensor shield option for improved sensor protection. In these applications where the thermal properties of the fluid are known and relatively constant during actual operation, thermal flowmeters can be used to measure the mass flow of the fluid because the thermal flow measurement is not dependent upon the pressure or temperature of the fluid. In a typical thermal flowmeter, a measured amount of heat is applied to the heater of the sensor. An insertion thermal mass air flow sensor provides precision measurement of total mass flow rate of gases flowing through closed conduits such as pipes and ducts.

These guides can be attached to the pipe with a band clamp, a C-clamp, or a chain clamp. The display can be programmed to select the desired mode of operation, and labels are furnished to indicate which mode is being used. While KOBOLD offers a wide variety of instrumentation that meets most standard application needs, we are also able to meet extraordinary application needs that can be hard to find solutions for. © Copyright 2020 Sierra Instruments, Inc. All Rights Reserved. The transmission distance can over 1000m. Your email address will not be published. Our familiarity with exotic materials allows us to offer solutions for variables that are frequently hard to accommodate. The accuracy is medium only and they are used primarily for gas. In accordance with the CE requirements of EMC Directive 89/336/EEC, ROHS Directive 2002/95/EY, Pipe Properties Calculator(For Windows 7,8), Pitot Static Tube Online Calculation For Compressible and Incompressible Flow and Liquid, Airflow Instruments Multi-Function Anemometer Ta465, Airflow Instruments Rotating Vanes Lca501, Thermal Mass Air/Gas Flow Meter for Municipal Water Disinfection, Insertion Flowmeter for Compressed air & gases - EE-776. Thermal Mass Flow Meters FCI designs, manufactures and sells a broad line of thermal mass flow meters for air and gas flow measurement. Chinese, Questions? No pressure loss. *Verified by an independent NIST & NVLAP accredited lab, QuadraTherm 640i /780i Series Technical Datasheet, qMix Gas Mixing Feature Instruction Manual, QuadraTherm 640i/780i Series Instruction Manual, QuadraTherm 640i/780i Series Quick Installation Guide, QuadraTherm 640i/780i Series Product Software (SIP), (Mailing and Shipping Address) The amount of heat lost from the sensor is dependent upon the sensor design and the thermal properties of the fluid. The QuadraTherm® 640i is the most accurate insertion-probe thermal mass flow meter for air / gas mass flow rate measurement on the market today, achieving gas mass flow rate accuracy never before possible, +/- 0.75% of reading above 50% of full scale. Provides a moving average of the flow rate over a user-specified averaging period. The transmitter uses the heat input and temperature measurements to determine fluid flow. The FastFlo™ 620S is an insertion thermal mass air flow meter designed to give you a highly reliable, responsive and affordable mass flow meter for light industrial applications where a NEMA 4X (IP65) enclosure is acceptable. Home » Ultrasonic Flow Meters » Ultrasonic Insertion Flow Meter. Always on the leading edge, we offer a comprehensive portfolio of reliable instrumentation that is found in a vast array of applications all over the world. Thermal dispersion technology for direct mass flow measurement features: no pressure or temperature compensation needed, no moving parts, low pressure drop, and high turndown. Choose from our selection of inline flowmeters, including over 750 products in a wide range of styles and sizes. It can also be used to measure corrosive conductive liquids such as acid, alkali and salt. $1,755.00 Applications include calculating required fill or drain times for tanks, water towers, backflow prvention, heat exchangers, and oil & gas equipment.

The CDI 25 is designed for low-cost measurement of air usage at every piece of equipment in an industrial plant. If you have any questions, please contact our sales engineers. Thermal flowmeters can be applied to clean, sanitary, and corrosive gases where the thermal properties of the fluid are known. Insertion Flow Meter inserts pipe. It can measure even liquids such as water, sea water, oil, and slurry. CDI 5400 flowmeters make localized metering of air usage a practical way to manage a compressed-air system.

Some of this heat is lost to the flowing fluid. One male end, one female end (25-PS-EXT), 24 VDC wall plug power supply and extension cord for 5000 Series meters (5200-PS), 24 VDC wall plug power supply, built-in jack, and extension cord for 6000 Series meters (6000-PS-WP), 24 VDC DIN rail mount power supply for 6000 series meters (6000-PS), Learn more about this technology, the manufacturers, the users and the applications here, 1796 East 9 Mile Road, Hazel Park, MI, 48030, US, Mass flow measurement via thermal dispersion, Surge suppression; suitable for distributed DC power, Rate, Minimum, Average, and Total display options, User-adjustable minimum-flow and average-flow alarms. https://schema.org/InStock, Your email address will not be published. Thermal Dispersion Flow Meter for Air & Gasses - Insertion Style. An average-flow alarm indicates excessive usage. CDI 5200 flowmeters make localized metering of air usage a practical way to manage a compressed-air system. If you ever want to move or remove your CDI flowmeter, these rings plug and cover the holes that are left behind. Mixtures, such as flue stack flow and biogas flow, can be measured when their composition is known.

Each QuadraTherm thermal flow meter comes with onboard qMix(tm) gas mixing software which allows you to create custom gas mixtures in the field to compensate for gas compositional changes-no costly recalibration needed. They can also used in chemical and petrochemical plants when the thermal properties of the gas are known.

In these applications, varying composition of the fluid during actual operation can affect the thermal flow measurement. Adjustable Insertion Electromagnetic Flow Meter FMG900-Series. The metal paddle-wheel flow meter or flow monitor is easily inserted into the process piping via a threadolet or suitable fitting.

A minimum-flow alarm indicates leakage by blinking if flow does not drop below a specified level. Calculations include air flow, wet bulb, dew point, and turbulence. Sino-Instrument support customer customization and OEM, Copyright © Sino-Inst www.drurylandetheatre.com Flow, Level, Pressure Measurement Instrument Supplier, China.

Thermal-dispersion mass-flow technology gives the meter sensitivity to low leakage flows, while an innovative mounting design makes it easy to install.

It features ONICON's unique hot tap design that allows for easy insertion or removal from the pipe without the use of special tools and without disrupting flow. In other words, thermal flowmeters are often not suitable for applications with fluids that have varying composition and unknown components. Overview. The amount of heat lost is sensed using temperature measurement(s) in the sensor. Applications of special interest are circulating lubrication fluid, cooling water, industrial gas, corrosives and brine. This site uses cookies to improve your browsing experience. Kurz multipoint insertion flow meters use up to four sensors for measurement redundancy and to ensure accuracy. We also offer other instrumentation that can handle excessive amounts of flow, pressure, and temperature.

The 454FTB supports process temperatures from -40° C to 260° C and from -40°C to 500° C, process pressure ratings up to 300 PSIG, and a velocity range from 0 to 24,000 SFPM. By continuing to use our site, you agree to our use of cookies.

Mass Air Flow Meter Operating Principle: Thermal dispersion technology provides direct mass air flow measurement featuring no pressure or temperature compensation needed; no moving parts; low pressure drop; and high turndown. In stock and ready to ship.

Available in either an insertion version or inline version, this mass flow meter includes Sierra’s proprietary Raptor OS operating system. QQ: 1833768980 These alarm functions draw attention to waste without requiring central monitoring. When liquid flows through the pipe, this results in subsequent rotation of the affixed paddle wheel. Sierra Instruments

With the EE776 the consumption of compressed air.

It can also be installed on the cement pipeline; The special hole-opening tool used can make the sensor be installed under pressure without stopping production. Features Of Ultrasonic Insertion Flow Meterw Meter, Specifications of Ultrasonic Insertion Flow Meterw Meter, Inaccurate level measurement of liquid ammonia storage tank, Best Guide to Ultrasonic Level Transmitter, Beginner’s guide to HART Communicators-HART Protocol, (Best Price) Magnetic Flow Meter Manufacturers, SI3151AP-GP-Gauge pressure-Absolute pressure transmitter.pdf, SM3151DP-HP Differential Pressure-High Static Pressure Differential Pressure Transmitter.pdf, SM3151LT liquid level (pressure-differential pressure) transmitter.pdf, SMT3151FTLT flange threaded liquid level (pressure) transmitter.pdf, SMT3151TGP-TAP Direct Mount Pressure-Absolute Pressure Transmitter (T Type).pdf, SMT3151TLT Direct-mounted level (pressure) transmitter.pdf, SMT3151WTLT external thread liquid level (pressure) transmitter.pdf, Industrial Tank level indicators and Tank Level Gauges, 5 Industrial Propane Tank Level Indicators for Industrial Tank Level Measurement, Radar Level Measurement System for High Temperature Blast Furnace, Buyer’s Guide: Flow Technology-Turbine Flow Meter, Flow: over 1%-2%(battery-powered supply over ±2% ),Heat: over ±2%,Repeatability: over 0.2%, 2×20 character LCD with backlight, support the language of Chinese, English and Italy Convertor dimension:170*180*56cm, Support 16 key light touch keyboard and the Simulation keyboard software, 1 way 4~ 20mA output, electric resistance 0~ 1K,accuracy0.